SERVICE TIPS
81
Dometic
REFRIGERATORS
Models
RM2612 RM2812
RM2652 RM2852
OS1927 4/96
Copyright 1996 The
Dometic
Corporation
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - SERVICE TIPS

SERVICE TIPS81 DometicREFRIGERATORSModelsRM2612 RM2812RM2652 RM2852OS1927 4/96Copyright 1996 The Dometic Corporation

Página 2 - REFRIGERATOR SECTION

HIGH VOLTAGE CABLEDisconnect high voltage cable from electrode. If sparking starts during trial-for-ianition, the cable isgood. If there is no sparkin

Página 3

Next, do the same voltage test at the lower circuit board. Red wire (-) negative plug 1, terminal 5, togreen wire, plug 1, terminal 1 and black wire,

Página 4 - REFRIGERATOR CONTROL

A.B.rDC VOLT: ALL TESTS ARE TO BE DONE WITH THE REFRIGERATOR IN THE COOLING MODE.Measure volts between terminal J4 and the ground strip.AC MODE: Check

Página 5 - OPERATING MODES

CLIMATE CONTROL HEATERTo check the switch, disconnect the wires and do a continuity check. In the OFF position, there shouldbe no continuity. In the O

Página 6 - AC VOLTAGE REQUIREMENTS

SECTION 7LP GAS COMPONENTSMANUAL GAS SHUTOFF VALVETo check the shutoff valve, remove and inspect for any obstructions.GasConnection Manual GasShutoff

Página 7 - DC VOLTAGE REQUIREMENTS

THERMOCOUPLE . .The thermocouple should produce 25 to 35 millivolts when connected to the lower circuit board. Anyreading below 18 millivolts could ca

Página 8 - DC COMPONENTS

@-BURNER HOUSING@CHASSISGROUND@-CICCUI~ BOARD DISPLAY@-CIRCUIT BOARD POWER@--ELECTRODE@FUSE 3A@-FUSE 5A@HEATER 120V AC-HEATING CABLE@LIGHT@--PROTECTI

Página 9 - CHESTERLAND OH 44026

AIR LEAKSCheck the gasket on the doors to be sure of a positive air seal. Close the door on a dollar bill, then pullthe dollar bill out. If a gasket i

Página 10

C. When the front strip is in place, install one screw through the hinge and into the floor. The secondscrew is installed with a washer on the opposit

Página 11

D. Replace the top decoration panel.Third: Two screws installed as shown in rear base.DOOR POSITIONThe door position can be checked by observing any m

Página 12

THE MOST COMMON SYSTEM PROBLEMS ASSOCIATED WITH THERM2612, RM2812, RM2652, RM2852 REFRIGERATORSSYMPTOM. .CAUSEREFRIGERATOR SECTION1. No operation - no

Página 13

To check the cooling unit, first verify the AC heating element is good. Then place approximately onegallon of water inside the refrigerator and place

Página 14 - LP GAS COMPONENTS

SYMPTOMCAUSE7. Insufficient cooling on Gas - cools properly onAC mode.8. Freezes.9. Check light on.10. Interior light on when door is closed.11. Rapid

Página 15

DISPLAY PANEL(RM2652, RM2852) LEGEND 2-WAY MODEL1. Main Power Button ON/OFF2. AUTO/MANUAL Mode Selector ButtonA. AUTO Mode indicator lampB. CHECK indi

Página 16 - EST POINT

START-UP INSTRUCTIONSBefore starting the refrigerator, check that all the manual gas valves are in the ON position. DO NOT forgetthe manual shutoff va

Página 17

If 120 volts AC becomes available while the CHECK indicator lamp is on, the control system will switch to120 volt AC operation, The CHECK lamp will no

Página 18

COMPONENTS-HEATING ELEMENTRemove the heater leads from the lower circuit board and measure for proper resistance across thetwo leads.You should obtain

Página 19

The operational range of the unit is a minimum of 9.6V DC to a maximum of 22V DC. At 22V DC, theunit will automatically shut down until voltage has de

Página 20

SOLENOID VALVECheck the solenoid coil with a properly calibrated ohm meter. Remove the connector from the solenoidand measure the resistance across th