Installing the Channel Mark 6, Model
12E,
rated 25 MA
can result in failure to ignite on gas if the DC power
supply is below 12.5 volts DC. The reignitor will see low
voltage and not produce a spark, resulting in flame
failure lockout.
Installation of the Channel Products, Inc., Gasliter
Mark 6, Model
12E,
will VOID the Warranty on the
refrigerator.
D.
Electrode
First, do a visual check for cracks or breaks on the
ceramic insulator. Verify the mounting bracket is
attached properly to the electrode. If either of the
above is found, replace the electrode. The spark
gap must be set at three sixteenths
(3/16)
of an
inch and tip of electrode above
burner as shown below.
the slots in the
ELECTRODE
BURN
E.
The Solenoid Valve
receives DC power when the
AMES/AES
control selects LP gas operation. The
solenoid coil opens an internal valve seat and
allows gas to follow to the main orifice.
Check the solenoid valve with a properly cali-
brated ohm meter. Remove one of the connectors
from the solenoid and measure the resistance
across the terminals. The proper reading would
be 44-53 ohms.
Hook a manometerto the test port. With DC power
supplied to the solenoid terminals, a gas pressure
reading of 11-12 inches of water column should
be present. If no pressure or low pressure is
present at the test port, the gas solenoid is defec-
tive and should be replaced. NOTE: Verify the LP
gas system pres-
sure before replac-
ing a valve with low
pressure.
F.
The Power Module
monitors the DC and AC
power supplied to the refrigerator. It coordinates
the operation between DC, AC and gas in con-
junction with the setting of the display panel.
Check the fuse(s) under the cover on the power
module for continuity. Replace with same size if
bad. Inspect for a loose relay and Plug 3 (P3) on
the board. If loose, replace board. See FIG. 6.
When the refrigerator requires additional cooling,
the power module will send DC voltage to the
solenoid and reignitor. The trial-for-ignition will
last for 45 seconds and at the end of this period,
the check light will come on if there is no flame.
NOTE: When the thermocouple output is between
7-l 3 millivolts DC, the DC voltage to the reignitor
will be turned off. If the flame is extinguished, the
power module will not supply DC power to the
reignitor until the millivolts DC drop to 7-13
MVDC. It may take 1 O-l 5 seconds for the thermo-
couple to cool.
The PAL@ Tester will allow for proper testing of
the integrity of the upper and lower circuit cards.
The
PAL@
Tester is available from your
Dometic
parts distributor. See G.
Control Panel”.
I
FIG.
6
P1
P3
G. Control Panel
1) With the main ON/OFF switch on the control
panel in the OFF position:
Check for DC voltage at Plug 1
(P1)
Terminal 4
of lower circuit board. See FIG. 6.
If no voltage, check the fuse condition on lower
circuit board. Replace if blown. Check for DC
between J4 and
J10 on the lower circuit board.
If fuse is good and there is DC voltage at J4,
remove and replace lower circuit board. See
FIG. 6.
3