6
OPTION 3
The Innovator Refrigerator Ventilation System
B. THE INNOVATOR VENTILATION SYSTEM FOR SINGLE DOOR ABSORPTION REFRIGERATORS WITH TWO SIDE
VENTS.
This Innovator Ventilation System is for use with Dometic's single door refrigerators in applications where existing minimum
vent heights are reduced. The table below shows the innovator vent height that can be used when the innovator power ventilator
kit is used. The innovator power ventilator kits purpose is to assist required air movement across the refrigerator condenser
to ensure optimum performance.
See Installation Instructions packaged with the Innovator Ventilation System 3108705.751, Patent and 3108705.744
(Patent No. 5,355,693).
Important: Must be used with certified upper and lower side vents and installed per Option 2 Specifications
except for "A" min. dimension.
Note: When lower vent frame is higher that the refrigerator compartment floor: 2 (two) holes 1-3/4 inches in diameter (1sq
in. per hole free area) and covered with (14 x 14 per inch min.) screen are required to vent the heavier that air gasses to the
out-of-doors.
Note: See Pages 12 through 16 for approved Dometic Refrigerator vent options.
Model
No. A B C D * E
RM2193 20 20-7/8 4 1 1
RM4223 20 24-1/2 4-1/2 0 1
RM2332 37 21-3/8 4 1 1
RM2352 34 21-3/8 4 0 1
RM2353 34 21-3/8 4 0 1
RM2333 37 21-3/8 4 1 1
RM2410 33 24 4 0 1
RM2452 36 24 4-1/2 0 1
RM2453 36 24 4-1/2 0 1
RM2510 37 24 4 0 1
RM2551 44-1/2 24 4 0 1
RM2554 44-1/2 24 4 0 1
Max.
Dim.
Innovator
Vent Height
Min.
Dim.
Min.
Dim.
Max.
Dim.
(Dimensions in Inches)
* When dimension "D" exceeds 1", it is necessary to add baffle (E) above lower access vent, as
shown, for more efficient operation in warm temperatures.
E
TWO I-3/4" DIA
SCREEN COVERED
HOLES
HOLES MUST BE
CLEAR OF ANY
OBSTRUCTION