Dometic VACUUM GENERATOR Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para não Dometic VACUUM GENERATOR. Dometic VACUUM GENERATOR User Manual [de] [en] [fr] Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 2
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Before installing the vacuum generator,
you must consider the following:
1. Vacuum generator must be mounted
horizontally only.
2. The vacuum generator can be mount-
ed up to 50 feet (15.2 m) from the
VacuFlush toilet, and 30 feet (9.1 m)
from the holding tank.
3. The vacuum generator inlet must not
be mounted more than 6 feet (1.8 m)
higher than the toilet discharge outlet.
4. The maximum head pressure on the
discharge of the vacuum generator
must not exceed 6 feet.
Note: Two-toilet systems require a
vacuum generator for each toilet. This
method provides the benefit of a totally
redundant operating toilet in case of failure
in one toilet.
Installing the vacuum generator
1. Make sure the vacuum generator is properly located before proceeding. Place the vacuum generator on the
surface to be mounted. Position as needed. Using a center punch, mark the four slotted holes in the pump
feet. Remove vacuum generator.
2. Using a 3/16-inch drill bit, drill the four mounting holes. Use #14 wood screws and washers to secure vacuum
generator.
3. Position pump body to accommodate plumbing layout, if necessary, by loosening four fasteners that hold pump
onto vacuum tank, rotating pump body to desired position, and retightening fasteners.
4. Spin-nut connections on inlet and outlet fittings allow easy installation and positioning of hoses. Use two hose
clamps for each connection.
Reminder: For proper operation, the vacuum generator must be mounted horizontally. Make sure to connect the
discharge hose from the VacuFlush toilet to the inlet fitting of the vacuum generator.
Reminder: The best system will position the vacuum generator at the same level or lower than the VacuFlush
toilet.
Dimensional
Specifications
J-Series Vacuum Generator Components
Electrical
Specifications
J-Series Vacuum Generator
Installation Instructions
Dometic Corporation • Sanitation Systems
13128 State Rt. 226, P.O. Box 38
Big Prairie, OH 44611-0038 USA
330-496-3211
1-800-321-9886 • Fax: 330-496-3097
® Registered; ™ Trademark of Dometic Corporation
© Dometic Corporation
VACUUM
SWITCH
VACUUM
TANK
INLET FITTING
OUTLET
FITTING
PUMP MOTOR
VACUUM
PUMP BODY
Model Volts (DC) Power Draw GPM (LPM) Fuse/Breaker Wire Size Lbs. (Kg)
VG412 12 6 amp (avg.) 5.1 (19.3) 10 amp
follow ABYC
recommendations
15.1 (16.9)
VG424 24 3 amp (avg.) 5.1 (19.3) 5 amp 15.1 (16.9)
Vista de página 0
1 2

Resumo do Conteúdo

Página 1 - Installation Instructions

Before installing the vacuum generator, you must consider the following:1. Vacuum generator must be mounted horizontally only.2. The vacuum generat

Página 2

Wire the vacuum generator as shown in the wiring diagram. Use multistranded copper wire. Protect the wiring by installing grommets or other protective

Comentários a estes Manuais

Sem comentários