Dometic RM 7400(L) Manual de Serviço

Consulte online ou descarregue Manual de Serviço para Frigoríficos Dometic RM 7400(L). Dometic RM 7400(L) Service manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 52
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
DOMETIC
Dometic
MANUAL REFRIGERATOR
DIAGNOSTIC SERVICE
MANUAL
The
Dometic
Corporation
Corporate Office
Warranty
Department
2320 Industrial Parkway
Elkhart, IN 46515
219-295-5228
205 E. Fenn St.
LaGrange, IN 46761
219-463-2191
Technical Services
Department
509 S. Poplar St.
LaGrange, IN 46761
219-463-4858
OS1286
8/89
D-l
Diagnostic Service Manuals
Manual Compliments of
Northwest RV Supply
Printed From
http://www.nwrvsupply.com
Vista de página 0
1 2 3 4 5 6 ... 51 52

Resumo do Conteúdo

Página 1 - http://www.nwrvsupply.com

DOMETICDometicMANUAL REFRIGERATORDIAGNOSTIC SERVICEMANUALThe Dometic CorporationCorporate OfficeWarrantyDepartment2320 Industrial ParkwayElkhart, IN

Página 2

(1)This is Dometic’s Manual Refrigeration Diagnosis and Troubleshooting program. In this programwe will discuss the way an absorption cooling unit ope

Página 3

(4)The cooling unit parts that accomplish this‘cooling’ or heat extraction process, include the:Boiler or Generator(5)Condenser(6)EvaporatorPUMP BOILE

Página 4

(7)AbsorberABSORBERTHE ABSORPTION SYSTEMCONDENSEREVAPORATORBecause the self-contained cooling unitdoes not utilize an electric compressoror pump, the

Página 5

(10)We will now take a closer look at how thecooling unit functions in normal operation.When proper heat is supplied to the boiler,ammonia vapor is pr

Página 6

U 3)As this process continues, the ammonia andhydrogen vapors become intermixed and flowdownward into the absorber vessel. As theammonia vapor comes i

Página 7

(16)Since the absorption system utilizes nomechanical pumps or compressors to circulatethe refrigerant within the system, proper levelingis required t

Página 8

(19)In recent years Dometic has engineered a newtype of cooling unit that utilizes an improvedsiphon pump tube design which drasticallyreduces the pos

Página 9

(22)The coach vent system must be able to providea way to direct the hot air, produced by theaction of the cooling unit, out away from theinstallation

Página 10

(25)Three things must be rememberedwhen diagnosing a cooling unit:First, circulation within the cool-ing unit is totally gravitational. Thismeans prop

Página 11

(28)One of the faults with a cooling unit isa blockage. This can happen when theunit is operated off-ievel, or if too muchheat has been applied to the

Página 12

NOTES:D-2Manual Compliments of Northwest RV Supply Printed From http://www.nwrvsupply.com

Página 13

(31)Let’s look at the current Dometic refrigeratorsand see how the gas flows.(32)Gas flows from the gas line to the shut-off valveand to the connectio

Página 14

(36)and onto the orifice and burner assembly.Remember that except for the connection piece,all fittings are O-ring sealed. Whenever thesystem is separ

Página 15

(40)The most efficient way to diagnose the gassystem would be to first connect the gasmanometer to the pressure test point. With thethermostat set at

Página 16

Turn on the main gas supply and take areading. If the manometer now reads 11 inches,the thermostat is defective and must bereplaced.(45)If the by-pass

Página 17

(47)Once the gas has been allowed to passthrough the safety valve, it flows to the gas jetand burner. These have been specificallydesigned to eliminat

Página 18

(51)The control assembly will now drop down andcan be pulled outward for service.(52)Pictured here is the other model design. Makesure the main gas su

Página 19

There are 3 screws in the burner area thatmust also be removed. Please note - these aremachine screws, not sheet metal type. It isimportant for them t

Página 20

The igniter reigniter, used on certain Dometicmodel refrigerators, operates on 12 volt current.On gas operation the igniter senses the resis-tance thr

Página 21

(67)Before an appliance can be sold to a recrea-tional vehicle manufacturer it must be testedand approved by a nationally recognizedtesting laboratory

Página 22

NOTES:D-7Manual Compliments of Northwest RV Supply Printed From http://www.nwrvsupply.com

Página 23

MANUAL REFRIGERATORDIAGNOSTIC SERVICE ‘MANUALTable of ContentsPageDiagnostic Flow ChartsNo Operation . . . . . . . . . . . . .No 12OV AC Operation . .

Página 24

Glossary of TermsMANUAL REFRIGERATION1.ABSORBER: Section of the cooling unit where the hydrogen and ammonia vapor are intermixedin the absorber. Ammon

Página 25

(Glossary of Terms . . continued)13.14.15.16.17.18.ORIFICE (JET):A small brass fitting that is mounted on the gas line just prior to the burner.This d

Página 26

TYPES OF BLOCKAGETo understand the absorption principle we have set up several refrigerators to inspect and diagnose.Carefully touch the absorber and

Página 27

CHANGING THEHINGE POSITIONqRefrigeratorBulletin R54/7A March 1987R54/7AMODELS: 2600,2602,2800,2802, 3600,3601,3800 & 3801IWHEN CHANGING THE HINGE

Página 28

(Bulletin R54/7A continued)5. Hold the door in its new position andcarefully retighten the hinge screws,being careful not to change the hingeposition.

Página 29

PROCEDURE FORCHANGING COOLING UNITThe following categories have been establishedpredicated on similarity of design and procedurefor replacement of coo

Página 30

(Bulletin R55/7A continued)INSTALL REPLACEMENT COOLING UNIT:1.2.3.4.5.6.7.Trim the Styrofoam portion of the coolingunit if it does not go freely into

Página 31

(Bulletin R55/7A) continued)2.3.4.5.6.7.Apply sealing permagum (sealing tape) onmounting plate (A; FIG. B5).Apply thermal mastic on the evaporator coi

Página 32

(Bulletin R55/7A continued)D. Category #4RM190RM2190RM2 192REMOVAL OF COOLING UNIT:1.2.3.4.5.Remove cover and flue tube, then disconnectburner from ch

Página 33

(Bulletin R55/7A continued)3FIG. El(A)SEALINGPERMAGUM(Sealing Tape)FIG. E2F. Category #63RM75RM76 RM77REMOVAL OF COOLING UNIT:1.2.3.3.5.Remove burne

Página 34

MANUAL REFRIGERATORDIAGNOSTIC FLOW CHARTNO OPERATIONA.1Check Supply Voltage1. 110 Volt Plug2. Wire SizeCorrect as NecessaryOKB.VCheck FuseCorrect as N

Página 35

(Bulletin R55/7A continued4. Tighten screws securely to obtain proper seal.5. Install heating elements completely back intothe pocket and plug in (FIG

Página 36

Before You ChangeThat Cooling UnitPART I. PROPER DIAGNOSISCooling units are sometimes diagnosed as beingdefective when the actual problem is something

Página 37

(Bulletin continued)FIG.A2Also,make sure the distance fromthe bottom of the refrigerator to theroof vent is at least the minimumdimension given in t

Página 38

[Bulletin R61/7A continued)B.1.33.4.PERFORMANCE TESTFirst perform all the preliminary checksdescribed previously.Remove all food from the refrigerator

Página 39

(Bulletin R61/7A continued)NOTE: The cooling units currently being usedare specially designed to prevent overheating ofthe boiler tube even when opera

Página 40

REFRIGERATOR TECHNICAL DATARAK1 00RAK1302l RC15RC65GRC65Kl RC150l RC150ARC1 50TEGRC 150TEGl RC152RC160ERC 160ERC1 60TEGRC 1 60TEGl M52l M709286111001

Página 41 - Cooling Unit

(Bulletin continued)RM3601 0173757022 17.9RM3604 2934803996 53 (2007419191)0173754045 2.5 48 ___0173757022 17.9RM3800 2934901097 58 (2007419217)017

Página 42

(Bulletin continued)l Models that use brass heating elements approximately in diameter.NOTE: The formula for calculating amps Watts Volts =

Página 43

BULLETIN 4 MAY 1983Replacement of cooling units in RM760.Cooling unit will replace 530A in production and service.When installing as replacement

Página 44

CROSS REFERENCE OFREFRIGERATORS MANUFACTURED BYA.B. ELECTROLUX AND PROCEDURE CHANGESREFRIGERATOR BULLETINREVISED AUGUST, 1984 SUBJECT: Dometicare Proc

Página 45

MANUAL REFRIGERATORDIAGNOSTIC FLOW CHARTNO 120 VOLT AC OPERATIONA.1. Check AC Power2. Refrigerator Plugged in3. Breaker4. Coach Plug Correct as Necess

Página 46

HEATING ELEMENTS 360-460-660-760Previous literature covering the following models, lists the wattage of 110 voltheading elements as follows:RM360120wa

Página 47 - Volts (120) Amps =

THE ABSORPTION SYSTEMWATER SEPARATORVAPOR PIPE SOLUTIONB SOLUTIONc LIQUID D VAPORE HYDROGEN GASF VAPORD-9-20Manual Compliments of Northwes

Página 48

This Manual is Compliments of Northwest RV Supply 86325 College View Road Eugene, OR 97405 Local: 541-746-9092 Toll-Free: 866-678-7467 Fax: 541-736

Página 49

MANUAL REFRIGERATORDIAGNOSTIC FLOW CHARTNO GAS OPERATION - Models Equipped with Piezo igniter.Check Gas SupplyOKB.Check SwitchINOT OKCorrect as Necess

Página 50

MANUAL REFRIGERATORDIAGNOSTIC FLOW CHARTNO GAS OPERATION - Models Equipped with Automatic ReigniterA.Check Gas PressureNOT OK Correct as Necessary(Pag

Página 51

NOTES:D-5Manual Compliments of Northwest RV Supply Printed From http://www.nwrvsupply.com

Página 52

OPERATION & DIAGNOSISOFDOMETICMANUAL REFRIGERATORSD-6-1Manual Compliments of Northwest RV Supply Printed From http://www.nwrvsupply.com

Comentários a estes Manuais