VENT INSTALLATION INSTRUCTIONS
FOR DOMETIC REFRIGERATORS
As Required by the American/Canadian Gas Associations
This manual must be read and understood
before installation, adjustment, service, or
maintenance is performed. This unit must be
installed by a qualified service technician.
Modification of this product can be extremely
hazardous and could result in personal injury
or property damage.
1. GENERAL INSTRUCTIONS
The vents outlined herein have been design certified by
A.G.A. under ANSI Z21.19 Refrigerator Standard for installa-
tion in a mobile home or recreational vehicle and are approved
by the Canadian Gas Association.
The certifications are, however, contingent on the instal-
lation being made in accordance with the following instruc-
tions as applicable.
In the U.S.A., the installation must conform with:
1. National Fuel Gas Code ANSI Z223.1 (latest edition)
2. Manufactured Home Construction and Safety Standard,
Title 24 CFR, Part 3280
3. Recreational Vehicles ANSI A119.2 (latest edition)
The unit must be electrically grounded in accordance with
the National Electric Code ANSI/NFPA 70 (latest edition)
when installed if an external alternating current electrical
source is utilized.
4. Any applicable local code.
In Canada, the installation must conform with:
1. Current CGA B 149 Gas Installation Codes
2. Current CSA Standard Z240.4 GAS-EQUIPPED REC-
REATIONAL VEHICLES AND MOBILE HOUSING
3. Any applicable local code
2. VENTILATION
The installation shall be made in such a manner as to
separate the combustion system from the living space of the
mobile home or recreational vehicle. Openings for air supply
or for venting of combustion products shall have a minimum
dimension of not less than 1/4 inch.
All joints in the enclosure must be sealed to
prevent gas leakage into the living area. Clear-
ance from the combustible materials must be
maintained as shown in the cross-section
views.
Proper installation requires one fresh air intake and one upper
exhaust vent. The ventilation kits shown in this instruction
manual have been certified for use with the refrigerator
models listed in the Table. For approved vents and refrigerator
vent options, see Pages 12 -16. The ventilation kits must be
installed and used without modification. An opening toward
the outside at floor level in the refrigerator compartment must
be provided for ventilation of heavier-than-air fuel gases. The
lower vent of the recommended kits is provided with proper
size openings. The flow of combustion and ventilation air
must not be obstructed.
The lower side vent is fitted with a panel which provides an
adequate access opening for ready serviceability of the
burner and control manifold of the refrigerator. This should be
centered on the back of the refrigerator.
When installing the refrigerator, the installer must block the
space between the storage cabinet and the top of the
refrigerator, otherwise heat will become trapped in this
space, making the top of the refrigerator hot, thus reducing
the efficiency of the unit.
For additional instructions not covered in this manual, see
Installation Instructions for the model of refrigerator being
installed.
3. CERTIFIED INSTALLATIONS
All options must have both an upper and lower side
vent, or a roof vent matched with a lower vent.
4. METHODS OF INSTALLATION
OPTION NO. 1
Consists of one roof vent and one lower side vent.
Recommended for normal installations where natural
draft ventilation is possible.
OPTION NO. 2
Consists of two side vents.
Natural draft ventilation on smaller single-door models
where Installation Option No. 1 is NOT possible.
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1

1REVISIONForm No.3109937.031 2/03(Replaces 3109937.023)(French 3109938.039)©2003 Dometic CorporationLaGrange, IN 46761VENT INSTALLATION INSTRUCTIONS

Página 2

10Model No.ABCDEFGHRM4290 32 20-1/4 31-1/2 20-3/4 9-1/4 7-1/2 1 5RM4292 32 20-1/4 31-1/2 20-3/4 9-1/4 7-1/2 1 5Max.Dim.Min.Dim.Min.Dim.Min.Dim.Max.Dim

Página 3 - OPTION 1

11Model No. A B B C C D * E FNDR1292 63 25 31 5-1/8 14 6 1 44-1/2NDR1492 63 25 31 5-1/8 14 6 1 44-1/2OPTION 5D. CONSISTS OF SIDE-BY-SIDE REFRIGERATOR

Página 4 - OPTION 2

12APPROVED DOMETIC REFRIGERATOR VENTSVENT NO. 1DOMETIC PLASTIC ROOF VENTVENT NO. 2DOMETIC (UPPER/LOWER) PLASTICSIDE VENTVENT NO. 3DOMETIC LOWER SIDE V

Página 5 - The Innovator Refrigerator

13APPROVED DOMETIC REFRIGERATOR VENTSVENT NO. 7THE INNOVATOR REFRIGERATORVENTILATION SYSTEM (PATENT #5,355,693)For Use with Single Door RefrigeratorsV

Página 6

14 VENT OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTIONMODEL NO. DESCRIPTION 1 2 3-A 3-B 3-C 3-D 3-E 4ROO

Página 7

15 VENT OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTIONMODEL NO. DESCRIPTION 1 2 3-A 3-B 3-C 3-D 3-E

Página 8

16 VENT OPTION OPTION OPTION OPTION OPTION OPTION OPTION OPTIONMODEL NO. DESCRIPTION 1 2 3-A 3-B 3-C 3-D 3-E

Página 9

2OPTION NO. 3The Innovator Refrigerator Ventilator SystemFor optimum performance and where Installation Options No. 1 and 2 are NOT possible:A. Consis

Página 10 - Consists of Two Side Vents

35-1/2"23-3/4" or Dimension"D" CENTERED*ALOWERACCESSVENTEINSIDEDIMENSIONBINSIDEDIMENSION*** DINSIDEDIMENSIONCINSIDEDIMENSIONModel

Página 11

4Model No.A*BCDEF**GRM2193(1) 20-5/8 20-7/8 20-7/8 17-3/4 4 1 1RM2193(2) 21-5/8 20-7/8*** 20-7/8 17-3/4 4 1 1RM2332 37 21-3/8 29-3/4 20-1/2 4 1 1RM235

Página 12

5 ACCESS PANELMODEL DIMENSIONSERIES A BRM2612, RM2620, RM2652,RM3662, RM3663, 22" 14"RM2812, RM2820, RM2852,RM3862, RM3863,

Página 13

6OPTION 3The Innovator Refrigerator Ventilation SystemB. THE INNOVATOR VENTILATION SYSTEM FOR SINGLE DOOR ABSORPTION REFRIGERATORS WITH TWO SIDEVENTS.

Página 14 - REFRIGERATOR VENT OPTIONS

7OPTION 3The Innovator Refrigerator Ventilation SystemC. INNOVATOR VENTILATION SYSTEM FOR SINGLE DOOR REFRIGERATORS WITH 2PLASTIC SIDE VENTSThe Innova

Página 15

8OPTION 3The Innovator Refrigerator Ventilation SystemD. INNOVATOR VENTILATION SYSTEM FOR DOUBLE DOOR REFRIGERATOR WITH 2 SIDE VENTSThe Innovator Vent

Página 16

9OPTION 3The Innovator Refrigerator Ventilation SystemE. INNOVATOR VENTILATION SYSTEM FOR SIDE-BY-SIDE REFRIGERATOR WITH 2 SIDE VENTSThe Innovator Ven

Comentários a estes Manuais

Sem comentários