5
Replace the top decoration panel.
Make sure the tabs snap back into the holes in the hinge
plate.
STEP 3: Two screws installed in the rear base.
See FIG. 8.
Failure to follow the sequence in securing the refrigerator
in the enclosure can cause leakage between the frame
and cabinet. Any space between the counter, storage
area or ceiling and top of the refrigerator greater than
40 mm should be blocked. The heat produced at the
rear of the refrigerator will become trapped in this space,
making the top of the refrigerator hot and reduce the
efficiency of the refrigerator.
LP GAS CONNECTION
The refrigerator is designed for operation on LP-gas, the
pressure of which must be 2,7 kPa for Propane.
Check that this is stated on the data plate.
The refrigerator is not designed for operation on
town gas or natural gas.
Hook up to the gas supply line is accomplished at the
manual gas valve, which is furnished with a ISO 7/1 -Rp
1/8 internal pipe thread connection. All completed con-
nections should be checked for leaks with soapy water.
FIG. 7
1
2
FIG. 8
DO NOT use a flame to check for gas leaks.
The gas supply system must incorporate an approved
gas pressure regulator to maintain a supply pressure of
2,75 kPa .
When testing the gas supply system at test pressures in
excess of 1/2 psi, the refrigerator and its individual shutoff
valve must be disconnected from the gas supply piping
system.
When testing the gas supply system at pressures less
than or equal to 1/2 psi, the appliance must be isolated
from the gas supply piping system by closing its indi-
vidual manual shutoff valve.
In case detailed instructions on the installation and con-
nection to the gas supply are required, contact your dealer
or distributor.
TESTING LP GAS SAFETY SHUTOFF
The gas safety shutoff must be tested after the re-
frigerator is connected to the LP gas supply.
To test the gas safety shutoff, proceed as follows:
1. Start the refrigerator according to the instructions for
LP Gas Operation. See section Operating Instruc-
tions.
2. Check that the gas flame is lit. This can be observed
on the flame indicator E. The red indicator is in the
green field, (ON).
3. Close the gas valve by turning the knob A back to
“OFF” position.
4. Wait for one minute.
5. Remove protection cover (see FIG. 1). Open the gas
valve by turning knob A to position “GAS” without
pushing the buttons C and D. Apply a non-corrosive
commercial bubble solution to the burner jet. Be care-
ful not to damage the burner jet.
6. No bubbles should appear at the opening of the burner
jet. The presence of bubbles indicates a defective
gas safety shutoff, and service is required.
7. If no bubbles were present at the burner jet, the gas
safety valve is working properly. Rinse jet thoroughly
with fresh water before proceeding. Be careful not to
damage the burner jet.
Replace the protection cover and turn the main switch
OFF and back ON. See instruction for LP Gas Op-
eration , section Operating Instructions. Normal op-
eration of the burner should return. Allow the burner
to operate for a minimum of 5 minutes.
! WARNING